Personal Activation Device

The Personal Activation Device is worn by all members of staff that require protection. It uses infra red and / or radio technology to generate a call and identify the location and user ID.

Enquire about the Personal Activation Device
STC Personal Activation Devices
The Guardian STC5 and STC8 Personal Activation Devices are worn by all members of staff that require protection. Both are programmable and offer a number of levels of "call" type. Once activated the personal activation device transmits the signal to the receiver units, along with the transmitters own unique ID code.

Features unique to the Guardian Personal Activation Device are the programmable User ID and the "retained" rip-out peg. Once activated using the "rip-out" activator, the STC Personal Activation Device can be released from the hand leaving the unit operating in a hands free mode.

There are two types of Guardian STC Personal Activation Devices available, as described below. Both of these are programmable and the programming options available are discussed in LIMK Configuration Kit Manual.
Picture

STC5 Infra Red Personal Activation Device
The Guardian STC5 Infra Red Transmitter Personal Activation Device comprises of Infra Red Transmitters, battery monitor circuit with confidence LED, push button activator and attack level "retaining peg" activation method. With the pin removed the unit will transmit the call signal for up to 8 minutes before shutting down to allow the call to be reset in the event of a hostage situation.

The Guardian STC5 transmits on a high infra red frequency as well as the standard infra red frequency. This means it is ideal for use on sites where high frequency switched lighting has been installed, and overcomes the potential problems associated with this type of lighting technology. It can also be used on older sites where the standard Guardian AIRX4 IR Receivers have been installed.

STC8 Dual Technology (IR + RF) Personal Activation Device
The Guardian STC8 Dual Technology Personal Activation Device comprises not only of infra red transmitters, battery monitor circuit with confidence LED, push button activator and attack level retained peg activation method, but also has a radio transmitter and aerial built into the unit. The unit, once activated, sends an Infra red signal as described above, and simultaneously sends the same codes via the radio transmitter.

This dual technology provides RF back up to the infra red, or additional coverage to larger external areas such as Staff Car Parks, where it is impractical to use infra red.

The Guardian STC8 transmits on a high infra red frequency as well as the standard infra red frequency. This means it is ideal for use on sites where high frequency switched lighting has been installed, and overcomes the potential problems associated with type of lighting technology. It can also be used on older sites where the standard Guardian AIRX4 IR Receivers have been installed.

Personal Activation Device Attachment Methods
The STC Clip fixing offers a wide range of flexibility for attaching the STC Personal Activation Device to the users clothing, and no longer relies on the wearer having a belt or belt loop to attach the Personal Activation Device to the clothing. All Personal Activation Devices are supplied with the STC Clip and G-clip as standard.

Although now superceded by the new STC Clip, the leather loop will continue to be available as an optional extra for those customers who prefer this method of fixing.
Picture

Call Types Available
  • Call - sends standard Staff Attack System first level call signal
  • Reset Only - sends Reset signal
  • Assistance - sends Nursecall System Assistance level call signal
  • Emergency - sends Nursecall System Emergency level call signal
  • Attack - sends standard Staff Attack System Attack level call
  • Priority - sends Nursecall System Priority call
  • Staff Present Only - sends Staff Present signal
  • Call Remote Reset - sends Staff Attack System first level call which can be reset remotely when received on a Nursecall System call point
  • Assist Remote Reset - sends Nursecall System Assistance level call that can be reset remotely when received on a Staff Attack System
  • Off - switches the activator to “Off” and effectively turns it into a battery test feature as the LED is still lit when activated
Click here to contact us
Company Profile
Company Information
Privacy & Cookies
Government Compliance
NOMS Compliant Staff Attack Systems
Staff Safety Alarms
Staff Protection
Patient Security
​Personal Alarm System
HTM Compliant Staff Attack
Personal Safety Alarm
​Patient Alarm
​Care Home Alarm
Health Department: HBN 03 01
HBN Compliant Staff Attack
Nursecall System
​Refuge Alarm
Toilet Alarm
Health Department: HTM 08 03​
HBN Compliant Nurse Call
Guardian Staff Safety Systems - Staff Protection, Patient Security, Personal Alarm and Nurse call systems +44(0)1403 713240 | sales@intercall.co.uk                                       ISO9001 Certified
Website development by AlphaQuad